Results: Harmonic Time History
Description
Generates a time history response for harmonic response solutions solved using the Vs Time option.
The Vs Time option of the Harmonic Response solver calculates the maximum response of each included load case. During post-processing, those results can be combined to obtain the response as a function of time.
The load factors and the cases to be included in the harmonic time history, including load combination with linear static results, is set up in CASES: Harmonic Time.
Dialog
Start time
Starting point of the time period of interest.
End time
End point of the time period of interest.
Steps
Total number of steps to be generated for the time period of interest.